Atotalpain
2021-06-14T02:14:28+00:00
小弟在成都做空调地暖销售,各位若有选购方面的问题可以提出来我帮你参考参考
如果有人有兴趣的话再聊聊经销商以及厂家的价格策略
[img]https://img.nga.178.com/attachments/mon_202106/22/-40rwQ2o-7u1mK2oT3cSsg-la.jpg.medium.jpg[/img][img]https://img.nga.178.com/attachments/mon_202106/22/-40rwQ2o-7mi8ZbT3cSsg-lc.jpg.medium.jpg[/img]
请大佬帮忙看看我家的空调和地暖报价以及品牌
[img]https://img.nga.178.com/attachments/mon_202106/22/-40rwQ2o-kym9ZwT3cSjd-sg.jpg.medium.jpg[/img]
[img]https://img.nga.178.com/attachments/mon_202106/22/-40rwQ2o-22m5ZwT3cSig-sg.jpg.medium.jpg[/img]
[img]https://img.nga.178.com/attachments/mon_202106/22/-40rwQ2o-ijjjZ1cT3cSyh-rk.jpg.medium.jpg[/img]
[quote][pid=526372084,27303272,1]Reply[/pid] Post by [uid=7943930]thank243[/uid] (2021-06-22 10:21):
成都地暖报价包找平吗?[/quote]这个看报价里边的清单,一般都是包含的,不排除有人只盯到低价而忽略项目不全,这种一般都是低价陷阱
[quote][pid=526376412,27303272,1]Reply[/pid] Post by [uid=12257561]zergud[/uid] (2021-06-22 10:36):
所以你们平常家用的到底做不做伸缩缝[/quote]我们是要做的
[quote][pid=526375855,27303272,1]Reply[/pid] Post by [uid=478755]掠风之殇[/uid] (2021-06-22 10:34):
成都地暖120平大概多少钱[/quote]两万多到三万这个区间吧,没有具体的配置给不了准确价格
Reply to [pid=526382801,27303272,1]Reply[/pid] Post by [uid=27262576]yaofbs[/uid] (2021-06-22 10:57)
空调的报价,注意看下边的红字,不含电源线这个有点扯淡,空调所涉及的电源线有两块,一块是内机电源线,一块是主机电源线,不含的都是听起来价格可能低一点,但是实际上你回头就要找装修公司掏钱
而且交叉施工,出了问题责任算谁的,所以你务必叫他把电源线算进去,至少内机的必须算,主机电源线如果不算,你就去拉一下配电箱到空调外机的距离,有多少米,回头找装修公司给你报价
另外空调的设计上,没有看到配置表和设计图,你这个大小合不合适我不知道,三菱重工虽然我不做,但是这个4W的话应该是高了一点,三菱重工海尔,听说过吧?另外工人的安装水平,工艺水平,这个你叫他发点图片我来看看
地暖的话,又是没有找平层的,你叫他加上,我不知道你这个是什么地方的,说老实话有点水,主管看样子是PPR做,在成都这边很少用PPR做了,热熔的,久了怕有隐患,还有控制系统也看不出来,盲猜一个没有吧,就一个主机温控,
小结:锅炉用的啥?找平费用?主管换PEX?是分路控制还是主机控制?
博世盖世6300(22kw)和威能vuw242(24kw),这两个锅炉怎么选,瑞好和佩耐德的管子怎么选?
Reply to [pid=526391837,27303272,1]Reply[/pid] Post by [uid=4566586]Paylight[/uid] (2021-06-22 11:27)
你面积多大,几个厕所,都能用,威能的生活热水会稳定和充足一点,我选瑞好,前提是纯进口那款
我家地暖锅炉用的博士的,4年了,从来没维护过,想问问,这个要做什么例行维护么? 管道清理,换水什么的
Reply to [pid=526401025,27303272,1]Reply[/pid] Post by [uid=43166880]人心如檮杌[/uid] (2021-06-22 11:58)
需要了,这个要交维保公司的人来,或者卖给你的公司,上门换个水,锅炉里边除垢,管道动不了,可以加点保护剂
[quote][pid=526389364,27303272,1]Reply[/pid] Post by [uid=341548]immessonia[/uid] (2021-06-22 11:18):
空调的报价,注意看下边的红字,不含电源线这个有点扯淡,空调所涉及的电源线有两块,一块是内机电源线,一块是主机电源线,不含的都是听起来价格可能低一点,但是实际上你回头就要找装修公司掏钱
而且交叉施工,出了问题责任算谁的,所以你务必叫他把电源线算进去,至少内机的必须算,主机电源线如果不算,你就去拉一下配电箱到空调外机的距离,有多少米,回头找装修公司给你报价
另外空调的设计上,没有看到配置表和设计图,你这个大小合不合适我不知道,三菱重工虽然我不做,但是这个4W的话应该是高了一点,三菱重工海尔,听说过[/quote]感谢大佬回复!果然专业人士出手效果不一样[s:ac:茶]
空调电源线预估增加费用5k
地暖重新报价了,回填大概80一平
施工图请大佬过目
[img]https://img.nga.178.com/attachments/mon_202106/22/-40rwQ2o-dfwoZiT3cSsg-qm.jpg.medium.jpg[/img]
[img]https://img.nga.178.com/attachments/mon_202106/22/-40rwQ2o-6cotZdT3cSsg-lc.jpg.medium.jpg[/img]
[img]https://img.nga.178.com/attachments/mon_202106/22/-40rwQ2o-ag5jZfT3cSsg-lc.jpg.medium.jpg[/img]
[img]https://img.nga.178.com/attachments/mon_202106/22/-40rwQ2o-etltZfT3cSsg-lc.jpg.medium.jpg[/img]
[img]https://img.nga.178.com/attachments/mon_202106/22/-40rwQ2o-ej0yK1xT3cSsg-lc.jpg.medium.jpg[/img]
[img]https://img.nga.178.com/attachments/mon_202106/22/-40rwQ2o-cnk2K1yT3cSsg-lc.jpg.medium.jpg[/img]
[img]https://img.nga.178.com/attachments/mon_202106/22/-40rwQ2o-93cnK27T3cSsg-lc.jpg.medium.jpg[/img]
[img]https://img.nga.178.com/attachments/mon_202106/22/-40rwQ2o-28zmK23T3cSsg-lc.jpg.medium.jpg[/img]
[img]https://img.nga.178.com/attachments/mon_202106/22/-40rwQ2o-24tkZdT3cSlc-sg.jpg.medium.jpg[/img]
[img]https://img.nga.178.com/attachments/mon_202106/22/-40rwQ2o-8hhsZbT3cSsg-lc.jpg.medium.jpg[/img]
[quote][pid=526454830,27303272,1]Reply[/pid] Post by [uid=27262576]yaofbs[/uid] (2021-06-22 15:31):
感谢大佬回复!果然专业人士出手效果不一样[s:ac:茶]
空调电源线预估增加费用5k
地暖重新报价了,回填大概80一平
施工图请大佬过目
[img]https://img.nga.178.com/attachments/mon_202106/22/-40rwQ2o-dfwoZiT3cSsg-qm.jpg.medium.jpg[/img]
[img]https://img.nga.178.com/attachments/mon_202106/22/-40rwQ2o-6cotZdT3cSsg-lc.jpg.medium.jpg[/img]
[img]./mon_202106/22/-40rwQ2o-ag5jZfT3cSsg-lc.j[/quote]这个工艺水平我真的。。。。
先说内容吧,你家这个地暖管道,分为主管和盘管,其中主管商家仍然是用的PPR,这个建议不要用,换成PEX,如果是当地没有这个工艺水平当我没说,盘管他已经换成了PEX,这个可以不换也可以换回PERT
另外没有看到有分水箱,就是装分水器的盒子,参考我发你的图片
价格么,我真羡慕,按他这个水平在成都的价格,砍他两到三成一点问题也没有,当然这个你只能尽力而为,每个地区的物价都不一样,我只是说我这边的
[img]https://img.nga.178.com/attachments/mon_202106/22/-40rwQ2o-62dyZbT3cSsg-lc.jpg.medium.jpg[/img][img]https://img.nga.178.com/attachments/mon_202106/22/-40rwQ2o-6zi1K2oT3cSsg-la.jpg.medium.jpg[/img][img]https://img.nga.178.com/attachments/mon_202106/22/-40rwQ2o-e2s0ZcT3cSsg-lc.jpg.medium.jpg[/img][img]https://img.nga.178.com/attachments/mon_202106/22/-40rwQ2o-2u0lZiT3cSsg-lc.jpg.medium.jpg[/img]
随便发两张我做的,他们的安装水平确实有限[img]https://img.nga.178.com/attachments/mon_202106/22/-40rwQ2o-77afZcT3cSsg-lc.jpg.medium.jpg[/img]
[quote][pid=526468460,27303272,1]Reply[/pid] Post by [uid=341548]immessonia[/uid] (2021-06-22 16:22):
这个工艺水平我真的。。。。
先说内容吧,你家这个地暖管道,分为主管和盘管,其中主管商家仍然是用的PPR,这个建议不要用,换成PEX,如果是当地没有这个工艺水平当我没说,盘管他已经换成了PEX,这个可以不换也可以换回PERT
另外没有看到有分水箱,就是装分水器的盒子,参考我发你的图片
价格么,我真羡慕,按他这个水平在成都的价格,砍他两到三成一点问题也没有,当然这个你只能尽力而为,每个地区的物价都不一样,我只是说我这边的
[img]./mon_202106/22/-40rwQ2o-62dy[/quote]感谢大佬,我坐标北京[s:ac:晕]
大佬怎么看出主管还是热熔的啊?
工艺不行的话会有啥后果吗?不行我换一家吧,北京有啥能推荐的么,太难了
空调选三菱的?这型号能行吗?
客餐厅42平,选1拖5合适不?
还有就是国产中央空调咋样?